SAF-MPMUX-MIB DEFINITIONS ::= BEGIN

-- Title:       SAF SAF_MPMUX MIB version 2.15 in concise format
-- Date:        2006.07.14
-- By:          Technical Support <techsupport@saftehnika.com>
-- changes:
-- 2010.02.09. - outputABCD R/W

IMPORTS
        enterprises,  NetworkAddress, IpAddress,
        Counter, Gauge, TimeTicks       FROM RFC1155-SMI
	OBJECT-TYPE                     FROM RFC-1212	
	DisplayString			FROM RFC1213-MIB
	TRAP-TYPE			FROM RFC-1215;

	
saf   	                OBJECT IDENTIFIER ::=   { enterprises 7571 }
--old saf_ft 	        OBJECT IDENTIFIER ::=   { enterprises 4858 }
tehnika			OBJECT IDENTIFIER ::=   { saf 100 }
microwaveRadio		OBJECT IDENTIFIER ::=   { tehnika  1}
pointToPoint		OBJECT IDENTIFIER ::=   { microwaveRadio 1 }

cfm22			OBJECT IDENTIFIER ::=   { pointToPoint 2 }
mpmux			OBJECT IDENTIFIER ::=   { cfm22 22 }

--mpmux ====================================================================
terminal			OBJECT IDENTIFIER ::=   { mpmux 1 }
--termProduct	Text  
--termDescription   Text
--termLocation      Text    promt>
--termVersion       Text
--termOperation	integer ok, error,
--termIduTemperature integer
--termRfCablePowerStatus	 integer off, ok, short 
--termRestart ???   integer write restart ??? 

baseband		OBJECT IDENTIFIER ::=   { mpmux 2 }
--bbVersion 	Text
--bbOperation     integer
--bbLinkCapacity  integer Kbits
--bbLinkCapacityDescr Text MUX 2M+2M+2M+2M
--bbLoopback      integer off, on
--bbSyncLostAlarm integer off, on

radio1			OBJECT IDENTIFIER ::=   { mpmux 3 }
--rf1Allarm   integer off,on
--rf1Version  Text
--rf1Side     integer low,high
--rf1Channel integer 
--rf1TxFrequency Text
--rf1RxFrequency Text
--rf1TxPower  integer dBm
--rf1RxState  integer error, low, ok
--rf1RxLevel  integer dBm
--rf1CableAtt integer dB
--rf1TxOut	   integer error, ok
--rf1TxPLL	   integer error, ok
--rf1RxPLL	   integer error, ok
--rf1OduTemperature integer
--rf1Humidity integer low, high		 
--rf1Loopback integer off, on
--rf1RxAlarmLevel integer dBm
radio2			OBJECT IDENTIFIER ::=   { mpmux 4 }
--look radio1
switchCtrl		OBJECT IDENTIFIER ::=   { mpmux 5 }
-- activeLink

modules			OBJECT IDENTIFIER ::=   { mpmux 6 }
m1   			OBJECT IDENTIFIER ::=   { modules 1 }
m2   			OBJECT IDENTIFIER ::=   { modules 2 }
m3   			OBJECT IDENTIFIER ::=   { modules 3 }
m4   			OBJECT IDENTIFIER ::=   { modules 4 }

--type     integer  e1(33),v35(37),bridge(43), f2bridge(242)
--description  Text
--version      Text
--speed    integer 2048 Kbits
--oper     integer none(0),booting(1),ok(2),testing(3),
--		   loopback(4),illegalSpeed(5),error(6)
--rx       integer none(0),ok(1),noSignal(2),noLink(3),rxAIS(4),error(5)
--tx       integer none(0),ok(1),txAIS(4),error(5)
--loopback integer off(0),on(1)
--rxInput  integer other(0),coax(1),rj45(2),v35(3)
--txMode   integer other(0),halfDuplex(1),fullDuplex(2)
--txClockSource integer  other(0),master(1),slave(2)
--txClockPhase  integer  other(0),normal(1),inverse(2)
--dataPolarity  integer  other(0),normal(1),inverse(2)

termProduct OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual name of the model."
        ::= { terminal 1 }

termDescription OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual description of the model."
        ::= { terminal 2 }


termLocation OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Textual description of location (same as PROMT>)."
        ::= { terminal 3 }

termVersion OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual version."
        ::= { terminal 4 }

termOperation OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                booting(1),            
		ok(2),
		testing(3),
		error(4)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "System operation."
        ::= { terminal 5 }

termIduTemperature OBJECT-TYPE
        SYNTAX  INTEGER(-128..127) 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { terminal 6 }

-- termRfCablePowerStatus OBJECT-TYPE
--      SYNTAX  INTEGER {
--              off(0),               
--              ok(1),
--		short(2),                 
--		error(3)
--              }
--      ACCESS  read-only
--      STATUS  obsolete
--      DESCRIPTION
--              "Look at termRf1CablePowerStatus and termRf2CablePowerStatus"
--      ::= { terminal 7 }

-- termUpTime OBJECT-TYPE
--         SYNTAX  INTEGER
--         ACCESS  read-only
--         STATUS  obsolete
--         DESCRIPTION
--                 "Integer variable."
--         ::= { terminal 8 }


-- termDownTime OBJECT-TYPE
--         SYNTAX  INTEGER
--         ACCESS  read-only
--         STATUS  obsolete
--         DESCRIPTION
--                 "Integer variable."
--         ::= { terminal 9 }

termFrameErrors OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Integer variable. "
        ::= { terminal 10 }

writeConfig OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  write-only
        STATUS  mandatory
        DESCRIPTION
                "Write Config"
        ::= { terminal 11 }

restartCPU OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  write-only
        STATUS  mandatory
        DESCRIPTION
                "Restart CPU"
        ::= { terminal 12 }

serialNumber OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Serial number"
        ::= { terminal 13 }

termRf1CablePowerStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),               
                ok(1),
		short(2),                 
		error(3),
		power-off(4)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Cable status from ODU1"
        ::= { terminal 14 }
termRf2CablePowerStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),               
                ok(1),
		short(2),                 
		error(3),
		power-off(4)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Cable status from ODU2"
        ::= { terminal 15 }

-- PW 1
power3V3PS1 OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "IDU power voltage +3.3V"
        ::= { terminal 16 }

power5VPS1 OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "IDU power voltage +5V"
        ::= { terminal 17 }

powerM5VPS1 OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "IDU power voltage -5V"
        ::= { terminal 18 }

powerODU1V OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "ODU power voltage (V)"
        ::= { terminal 19 }

powerODU1I OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "ODU power current (A)"
        ::= { terminal 20 }

powerODU1W OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "ODU power (W)"
        ::= { terminal 21 }
-- PW 2
power3V3PS2 OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "IDU power voltage +3.3V"
        ::= { terminal 22 }

power5VPS2 OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "IDU power voltage +5V"
        ::= { terminal 23 }

powerM5VPS2 OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "IDU power voltage -5V"
        ::= { terminal 24 }

powerODU2V OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "ODU power voltage (V)"
        ::= { terminal 25 }

powerODU2I OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "ODU power current (A)"
        ::= { terminal 26 }

powerODU2W OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "ODU power (W)"
        ::= { terminal 27 }

-- end PW 1 2

cpuUsage OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "CPU usage [%]"
        ::= { terminal 28 }

termBFrameErr OBJECT-TYPE
        SYNTAX  Counter
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Background block errors"
        ::= { terminal 29 }

termStatCountTime OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Stat. count. time"
        ::= { terminal 30 }

termErroredSecond OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Err. seconds"
        ::= { terminal 31 }

termSeverelyErroredSecond OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Severe err. seconds"
        ::= { terminal 32 }

termSyncLostTime OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Sync lost time"
        ::= { terminal 33 }

termAvailableTime OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Available time"
        ::= { terminal 34 }
termUnAvailableTime OBJECT-TYPE
        SYNTAX  Gauge
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Unavailable time"
        ::= { terminal 35 }

termBer OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual representation of BER"
        ::= { terminal 36 }
berAlarm OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The BER alarm"
        ::= { terminal 37 }
remoteAlarm OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The Remote alarm"
        ::= { terminal 38 }
systemAlarm OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The SYSTEM alarm"
        ::= { terminal 39 }

inputABCD OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The Input sensor"
        ::= { terminal 40 }

outputABCD OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Output relays"
        ::= { terminal 41 }

termBerInPwOf10 OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "The Power of 10 part of termBer"
        ::= { terminal 42 }

outputMaskABCD OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "The Output relay bit mask.
                If the correspondig bit is
                0 - the output bit can be changed manualy
                1 - the output bit changes automaticaly (according to sync lost, radio allarm etc.)"
        ::= { terminal 43 }

-- ****** Basebend ***************************************************
--bbVersion 	Text
--bbOperation     integer
--bbLinkCapacity  integer Kbits
--bbLinkCapacityDescr Text MUX 2M+2M+2M+2M
--bbLoopback      integer off, on
--bbSyncLostAlarm integer off, on

bbVersion OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual version."
        ::= { baseband 1 }

bbOperation OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                booting(1),            
		ok(2),
		testing(3),
		loopback(4),
		illegalSpeed(5),
		error(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "System operation."
        ::= { baseband 2 }

bbLinkCapacity OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { baseband 3 }

bbLinkCapacityDescription OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Textual version."
        ::= { baseband 4 }

bbLoopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),               
                digital(1),
		analog(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Loopback Integer variable."
        ::= { baseband 5 }

bbSyncLostAlarm OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),               -- none of the following
                on(1)                 -- Alarm ON
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The SYncLostAlarm."
        ::= { baseband 6 }

-- ****** Radio1 *****************************************************

rf1Operation OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                booting(1),            
		ok(2),
		testing(3),
		error(4),
		noDataFromODU(5)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Radio operation."
        ::= { radio1 1 }

rf1Alarm OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),               -- none of the following
                on(1)                 -- Alarm ON
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The RadioAlarm."
        ::= { radio1 2 }

rf1Version OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual version."
        ::= { radio1 3 }

rf1Side OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),               
                high(1)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The Side."
        ::= { radio1 4 }

rf1Channel OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio1 5 }

rf1TxFrequency OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual version."
        ::= { radio1 6 }

rf1RxFrequency OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual version."
        ::= { radio1 7 }

rf1TxPower OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio1 8 }

rf1RxState OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),               
                ok(1),
		error(2),
		loopback(3)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The rx State."
        ::= { radio1 9 }

rf1RxLevel OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio1 10 }

rf1CableAttenuation OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio1 11 }

rf1TxOut OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),               
                ok(1),
		off(2)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The Tx out."
        ::= { radio1 12 }


rf1TxPLL OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),               
                ok(1)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The txPLL."
        ::= { radio1 13 }

rf1RxPLL OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),               
                ok(1)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The rxPLL."
        ::= { radio1 14 }

rf1OduTemperature OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio1 15 }

rf1OduHumidity OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),               
                high(1)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ODU Humidity."
        ::= { radio1 16 }

rf1Loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),               
                on(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Loopback Integer variable."
        ::= { radio1 17 }

rf1RxAlarmLevel OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio1 18 }
-- new 2005.05.17
rf1txfstart OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio1 19 }
rf1duplexshift OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio1 20 }
rf1chstep OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio1 21 }
rf1chstart OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio1 22 }
rf1chend OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio1 23 }
rf1txpwmin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio1 24 }
rf1txpwmax OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio1 25 }
rf1txpwstep OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio1 26 }
--rf1subbands OBJECT-TYPE
--        SYNTAX  INTEGER 
--        ACCESS  read-only
--        STATUS  optional
--      DESCRIPTION
--              "Integer variable."
--      ::= { radio1 27 }


-- ****** Radio2 *****************************************************

rf2Operation OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                booting(1),            
		ok(2),
		testing(3),
		error(4),
		noDataFromODU(5)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Radio operation."
        ::= { radio2 1 }

rf2Alarm OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),               -- none of the following
                on(1)                 -- Alarm ON
                }
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "The RadioAlarm. -> rf1Alarm"
        ::= { radio2 2 }

rf2Version OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual version."
        ::= { radio2 3 }

rf2Side OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),               
                high(1)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The Side."
        ::= { radio2 4 }

rf2Channel OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio2 5 }

rf2TxFrequency OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual version."
        ::= { radio2 6 }

rf2RxFrequency OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual version."
        ::= { radio2 7 }

rf2TxPower OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio2 8 }

rf2RxState OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),               
                ok(1),
		error(2),
		loopback(3)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The rx State."
        ::= { radio2 9 }

rf2RxLevel OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio2 10 }

rf2CableAttenuation OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio2 11 }

rf2TxOut OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),               
                ok(1),
		off(2)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The Tx out."
        ::= { radio2 12 }


rf2TxPLL OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),               
                ok(1)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The txPLL."
        ::= { radio2 13 }

rf2RxPLL OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),               
                ok(1)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The rxPLL."
        ::= { radio2 14 }

rf2OduTemperature OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio2 15 }

rf2OduHumidity OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),               
                high(1)               
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The ODU Humidity."
        ::= { radio2 16 }

rf2Loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),               
                on(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Loopback Integer variable."
        ::= { radio2 17 }

rf2RxAlarmLevel OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { radio2 18 }

-- new 2005.05.17
rf2txfstart OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio2 19 }
rf2duplexshift OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio2 20 }
rf2chstep OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio2 21 }
rf2chstart OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio2 22 }
rf2chend OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio2 23 }
rf2txpwmin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio2 24 }
rf2txpwmax OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio2 25 }
rf2txpwstep OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { radio2 26 }
--rf2subbands OBJECT-TYPE
--        SYNTAX  INTEGER 
--        ACCESS  read-only
--        STATUS  optional
--      DESCRIPTION
--              "Integer variable."
--      ::= { radio2 27 }


-- switchCtrl ====================
activeLink OBJECT-TYPE
        SYNTAX  INTEGER {
                unknown(0),              -- none of the following
                link1(1),            
		link2(2),
		error(255)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 1 }

activeTx OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                link1(1),            
		link2(2),
		both(3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 2 }

preferedLink OBJECT-TYPE
        SYNTAX  INTEGER {
                unknown(0),              -- none of the following
                link1(1),            
		link2(2),
		error(255)
                }
        ACCESS  read-write
        STATUS  optional
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 3 }

forcedLink OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),              -- none of the following
                link1(1),            
		link2(2),
		error(255)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 4 }

switchMode OBJECT-TYPE
        SYNTAX  INTEGER {
                unknown(0),              -- none of the following
                freqDiv(1),            
                hotStandby(2),
		independent(3)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 5 }

odu1RxMax OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 6 }

odu2RxMax OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 7 }

odu1RxMin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 8 }

odu2RxMin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 9 }

rxDelta OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Integer variable."
        ::= { switchCtrl 10 }

rxBER OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Maximum value of allowed BER"
        ::= { switchCtrl 11 }

switchDelay OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Delay (s)"
        ::= { switchCtrl 12 }


switchEnabledForRxBer OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Enable/disable swithing for Rx and BER"
        ::= { switchCtrl 13 }

switchReason OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
"		100 - command SWITCH FORCE OFF
		101 - command SWITCH FORCE 1
		102 - command SWITCH FORCE 2
		103 - command SWITCH ACTIVE 1
		104 - command SWITCH ACTIVE 2
		105 - active ODU changed from 1
		to 2 because of power problems in ODU1
		106 - active ODU changed from 2
		to 2 because of power problems in ODU2
		107 - active ODU changed from 1
		to 2 because of cable problems in ODU1
		108 - active ODU changed from 2
		to 1 because of cable problems in ODU2
		109 - active ODU changed from 1
		to 2 because of SyncLoss problems when active ODU1
		110 - active ODU changed from 2
		to 1 because of SyncLoss problems when active ODU2
		111 - active ODU changed from 1
		to 2 because of RAI problems when active ODU1
		112 - active ODU changed from 2
		to 1 because of RAI problems when active ODU2
		113 - active ODU changed from 1
		to 2 because of RXLEV problems in ODU1
		114 - active ODU changed from 2
		to 1 because of RXLEV problems in ODU2
		115 - active ODU changed from 1
		to 2 because of BER problems when active ODU1
		116 - active ODU changed from 2
		to 1 because of BER problems when active ODU2"
        ::= { switchCtrl 14 }


-- ***** modules *********************************************************

-- ****** m1 **************************
m1Type OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),
		e1x1(30),               
		e1(33),               
		v35(37),
		bridge(43),
		eow64(100),
		e3(227),
		t1x4(74),               
		e1x4(78),               
		f1bridge(241),
		f2bridge(242),
                none(255)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The module type."
        ::= { m1 1 }

m1Description OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual description of the module."
        ::= { m1 2 }


m1Version OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Textual version."
        ::= { m1 3 }

m1Speed OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module data speed Integer variable Kbit."
        ::= { m1 4 }

m1Operation OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                booting(1),            
		ok(2),
		testing(3),
		loopback(4),
		illegalSpeed(5),
		error(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module operation statuss."
        ::= { m1 5 }

m1Rx OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
		ok(1),
		noSignal(2),
		noLink(3),
		rxAIS(4),
		error(5),
		noData(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Rx statuss."
        ::= { m1 6 }

m1Tx OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
		ok(1),
		noSignal(2),
		noLink(3),
		txAIS(4),
		error(5),
		noData(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Tx statuss."
        ::= { m1 7 }

m1Loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),               
                on(1),
		analog(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Loopback Integer variable."
        ::= { m1 8 }

m1RxInput OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                coax(1),
		rj45(2),
		v35(3),
                e3(4),
		db25unbalanced(5),
		db25balanced(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Rx Input."
        ::= { m1 9 }

m1TxMode OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                halfDuplex(1),
		fullDuplex(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx duplex mode."
        ::= { m1 10 }


m1TxClockSource OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                master(1),
		slave(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx clock source."
        ::= { m1 11 }


m1TxClockPhase OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                normal(1),
		inverse(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx clock Phase."
        ::= { m1 12 }

m1DataPolarity OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                normal(1),
		inverse(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module data."
        ::= { m1 13 }

m1ChanCount OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Number of data channels"
        ::= { m1 14 }

-- ****** m2 **************************
m2Type OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),
		e1x1(30),               
		e1(33),               
		v35(37),
		bridge(43),
		eow64(100),
		e3(227),
		t1x4(74),               
		e1x4(78),               
		f1bridge(241),
		f2bridge(242),
                none(255)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The module type."
        ::= { m2 1 }

m2Description OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual description of the module."
        ::= { m2 2 }


m2Version OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Textual version."
        ::= { m2 3 }

m2Speed OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module data speed Integer variable Kbit."
        ::= { m2 4 }

m2Operation OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                booting(1),            
		ok(2),
		testing(3),
		loopback(4),
		illegalSpeed(5),
		error(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module operation statuss."
        ::= { m2 5 }

m2Rx OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
		ok(1),
		noSignal(2),
		noLink(3),
		rxAIS(4),
		error(5),
		noData(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Rx statuss."
        ::= { m2 6 }

m2Tx OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
		ok(1),
		noSignal(2),
		noLink(3),
		txAIS(4),
		error(5),
		noData(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Tx statuss."
        ::= { m2 7 }

m2Loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),               
                on(1),
		analog(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Loopback Integer variable."
        ::= { m2 8 }

m2RxInput OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                coax(1),
		rj45(2),
		v35(3),
                e3(4),
		db25unbalanced(5),
		db25balanced(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Rx Input."
        ::= { m2 9 }

m2TxMode OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                halfDuplex(1),
		fullDuplex(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx duplex mode."
        ::= { m2 10 }


m2TxClockSource OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                master(1),
		slave(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx clock source."
        ::= { m2 11 }


m2TxClockPhase OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                normal(1),
		inverse(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx clock Phase."
        ::= { m2 12 }

m2DataPolarity OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                normal(1),
		inverse(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module data."
        ::= { m2 13 }

m2ChanCount OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Number of data channels"
        ::= { m2 14 }

-- ****** m3 **************************
m3Type OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),
		e1x1(30),               
		e1(33),               
		v35(37),
		bridge(43),
		eow64(100),
		e3(227),
		t1x4(74),               
		e1x4(78),               
		f1bridge(241),
		f2bridge(242),
                none(255)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The module type."
        ::= { m3 1 }

m3Description OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual description of the module."
        ::= { m3 2 }


m3Version OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Textual version."
        ::= { m3 3 }

m3Speed OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module data speed Integer variable Kbit."
        ::= { m3 4 }

m3Operation OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                booting(1),            
		ok(2),
		testing(3),
		loopback(4),
		illegalSpeed(5),
		error(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module operation statuss."
        ::= { m3 5 }

m3Rx OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
		ok(1),
		noSignal(2),
		noLink(3),
		rxAIS(4),
		error(5),
		noData(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Rx statuss."
        ::= { m3 6 }

m3Tx OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
		ok(1),
		noSignal(2),
		noLink(3),
		txAIS(4),
		error(5),
		noData(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Tx statuss."
        ::= { m3 7 }

m3Loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),               
                on(1),
		analog(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Loopback Integer variable."
        ::= { m3 8 }


m3RxInput OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                coax(1),
		rj45(2),
		v35(3),
                e3(4),
		db25unbalanced(5),
		db25balanced(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Rx Input."
        ::= { m3 9 }

m3TxMode OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                halfDuplex(1),
		fullDuplex(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx duplex mode."
        ::= { m3 10 }


m3TxClockSource OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                master(1),
		slave(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx clock source."
        ::= { m3 11 }


m3TxClockPhase OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                normal(1),
		inverse(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx clock Phase."
        ::= { m3 12 }

m3DataPolarity OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                normal(1),
		inverse(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module data."
        ::= { m3 13 }

m3ChanCount OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Number of data channels"
        ::= { m3 14 }

-- ****** m4 **************************
m4Type OBJECT-TYPE
        SYNTAX  INTEGER {
                error(0),
		e1x1(30),               
		e1(33),               
		v35(37),
		bridge(43),
		eow64(100),
		e3(227),
		t1x4(74),               
		e1x4(78),               
		f1bridge(241),
		f2bridge(242),
                none(255)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "The module type."
        ::= { m4 1 }

m4Description OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Textual description of the module."
        ::= { m4 2 }


m4Version OBJECT-TYPE
        SYNTAX  DisplayString (SIZE(0..255))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Textual version."
        ::= { m4 3 }

m4Speed OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module data speed Integer variable Kbit."
        ::= { m4 4 }

m4Operation OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                booting(1),            
		ok(2),
		testing(3),
		loopback(4),
		illegalSpeed(5),
		error(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module operation statuss."
        ::= { m4 5 }

m4Rx OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
		ok(1),
		noSignal(2),
		noLink(3),
		rxAIS(4),
		error(5),
		noData(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Rx statuss."
        ::= { m4 6 }

m4Tx OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
		ok(1),
		noSignal(2),
		noLink(3),
		txAIS(4),
		error(5),
		noData(6)
                }
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Module Tx statuss."
        ::= { m4 7 }

m4Loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),               
                on(1),
		analog(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Loopback Integer variable."
        ::= { m4 8 }


m4RxInput OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                coax(1),
		rj45(2),
		v35(3),
                e3(4),
		db25unbalanced(5),
		db25balanced(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Rx Input."
        ::= { m4 9 }

m4TxMode OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                halfDuplex(1),
		fullDuplex(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx duplex mode."
        ::= { m4 10 }


m4TxClockSource OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                master(1),
		slave(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx clock source."
        ::= { m4 11 }


m4TxClockPhase OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                normal(1),
		inverse(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module Tx clock Phase."
        ::= { m4 12 }

m4DataPolarity OBJECT-TYPE
        SYNTAX  INTEGER {
                other(0),               
                normal(1),
		inverse(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Module data."
        ::= { m4 13 }

m4ChanCount OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                "Number of data channels"
        ::= { m4 14 }

m1port1   			OBJECT IDENTIFIER ::=   { m1 21 }
m1port2   			OBJECT IDENTIFIER ::=   { m1 22 }
m1port3   			OBJECT IDENTIFIER ::=   { m1 23 }
m1port4   			OBJECT IDENTIFIER ::=   { m1 24 }
m2port1   			OBJECT IDENTIFIER ::=   { m2 21 }
m2port2   			OBJECT IDENTIFIER ::=   { m2 22 }
m2port3   			OBJECT IDENTIFIER ::=   { m2 23 }
m2port4   			OBJECT IDENTIFIER ::=   { m2 24 }
m3port1   			OBJECT IDENTIFIER ::=   { m3 21 }
m3port2   			OBJECT IDENTIFIER ::=   { m3 22 }
m3port3   			OBJECT IDENTIFIER ::=   { m3 23 }
m3port4   			OBJECT IDENTIFIER ::=   { m3 24 }
m4port1   			OBJECT IDENTIFIER ::=   { m4 21 }
m4port2   			OBJECT IDENTIFIER ::=   { m4 22 }
m4port3   			OBJECT IDENTIFIER ::=   { m4 23 }
m4port4   			OBJECT IDENTIFIER ::=   { m4 24 }

m1p1statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port1 1 }

m1p1connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m1port1 2 }

m1p1flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port1 3 }

m1p1priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port1 4 }

m1p1loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m1port1 5 }

m1p2statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port2 1 }

m1p2connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m1port2 2 }

m1p2flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port2 3 }


m1p2priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port2 4 }

m1p2loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m1port2 5 }

m1p3statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port3 1 }

m1p3connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m1port3 2 }

m1p3flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port3 3 }

m1p3priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port3 4 }


m1p3loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m1port3 5 }

m1p4statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port4 1 }

m1p4connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m1port4 2 }

m1p4flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port4 3 }

m1p4priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m1port4 4 }

m1p4loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m1port4 5 }

m2p1statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port1 1 }

m2p1connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m2port1 2 }

m2p1flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port1 3 }

m2p1priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port1 4 }

m2p1loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m2port1 5 }

m2p2statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port2 1 }

m2p2connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m2port2 2 }

m2p2flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port2 3 }

m2p2priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port2 4 }

m2p2loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m2port2 5 }

m2p3statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port3 1 }

m2p3connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m2port3 2 }

m2p3flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port3 3 }

m2p3priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port3 4 }

m2p3loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m2port3 5 }

m2p4statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port4 1 }

m2p4connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m2port4 2 }

m2p4flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port4 3 }

m2p4priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m2port4 4 }

m2p4loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m2port4 5 }

m3p1statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port1 1 }

m3p1connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m3port1 2 }

m3p1flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port1 3 }

m3p1priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port1 4 }

m3p1loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m3port1 5 }

m3p2statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port2 1 }

m3p2connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m3port2 2 }

m3p2flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port2 3 }

m3p2priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port2 4 }

m3p2loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m3port2 5 }

m3p3statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port3 1 }

m3p3connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m3port3 2 }

m3p3flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port3 3 }

m3p3priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port3 4 }

m3p3loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m3port3 5 }

m3p4statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port4 1 }

m3p4connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m3port4 2 }

m3p4flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port4 3 }

m3p4priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m3port4 4 }

m3p4loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m3port4 5 }

m4p1statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port1 1 }

m4p1connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m4port1 2 }

m4p1flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port1 3 }

m4p1priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port1 4 }

m4p1loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m4port1 5 }

m4p2statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port2 1 }

m4p2connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m4port2 2 }

m4p2flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port2 3 }

m4p2priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port2 4 }

m4p2loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m4port2 5 }

m4p3statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port3 1 }

m4p3connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m4port3 2 }

m4p3flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port3 3 }

m4p3priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port3 4 }

m4p3loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m4port3 5 }

m4p4statbin OBJECT-TYPE
        SYNTAX  INTEGER 
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port4 1 }

m4p4connection OBJECT-TYPE
        SYNTAX  INTEGER {
                none(0),              -- none of the following
                auto(1),            
		eth10fdx(2),
		eth10hdx(3),
		eth100fdx(4),
		eth100hdx(5),
		ds1(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Note: ds1 means E1 or T1"
        ::= { m4port4 2 }


m4p4flowcntrl OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(0),
                enabled(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port4 3 }

m4p4priority OBJECT-TYPE
        SYNTAX  INTEGER {
                low(0),
                high(1)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { m4port4 4 }

m4p4loopback OBJECT-TYPE
        SYNTAX  INTEGER {
                off(0),
                analog(1),
                remote(2),
                digital(4),
                remoteANDdigital(6)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "loopback"
        ::= { m4port4 5 }

--mpmux ==================================================================
        

alarmTrap	TRAP-TYPE 
		ENTERPRISE   mpmux 
		VARIABLES
		{            
		 rfAlarm,
		 bbSyncLostAlarm,
		 berAlarm,
		 remoteAlarm,
		 systemAlarm
		}
		DESCRIPTION
		"SAF management Alarm trap."                                
		::= 0

alinkTrap	TRAP-TYPE 
		ENTERPRISE   mpmux
		VARIABLES
		{            
		 activeLink
		}
		DESCRIPTION
		"SAF Active Link trap."                                
		::= 1
                           